Croma

Exprecell™ — Single syringe system for autologous PRP / Fluid-PRF

Closed single-syringe medical device for anticoagulant-free preparation of autologous platelet-rich plasma (PRP) / Fluid-PRF: 18 mL of venous blood, one 5-minute spin, approximately 8.5 mL of concentrate.

Exprecell™ Single Syringe System — packaging and device (Croma material)
2.3×Platelet concentration
≈ 8.5 mLPRP / Fluid-PRF yield
5 minSpin time
67.2%Platelet recovery
Clinical description

Exprecell™ is a medical device for the preparation of autologous platelet-rich plasma (PRP) as Fluid-PRF (platelet-rich fibrin in liquid form). The same device is used to aspirate venous blood, holds it during centrifugation and allows the concentrate to be drawn, in a closed system that limits exposure to external contaminants.

Preparation requires no anticoagulant and no separation gel, through a purely physical process: a single short spin of 5 minutes at 1,500 rpm (420 × g) in a swing-out rotor centrifuge. Without anticoagulant, Fluid-PRF is formed, a biologically active concentrate that retains the properties of platelets and leukocytes and stays liquid for a certain period of time. 18 mL of whole blood yield approximately 8.5 mL of PRP / Fluid-PRF.

In the pre-clinical comparative study published in 2026, platelet concentration increased 2.3-fold over baseline, within the range considered optimal by the literature cited by the manufacturer, and platelet recovery was 67.2%. Leukocytes were reduced by more than 95% and erythrocytes by more than 99%. The concentrate contains extracellular vesicles (such as exosomes), on average about 7.5 million/mL, 80% of them platelet-derived.

In short, following the manufacturer guide (full instructions are in the IFU): prepare the device, collect up to 18 mL of venous blood through a Luer-Lock needle (for example, a 21 G butterfly needle), centrifuge for 5 minutes, remove the thumb press and draw the yellow PRP layer into Luer-Lock syringes up to the maximum fill mark, then administer the concentrate aseptically, according to the intended treatment.

Indications
  • Aspiration of venous blood, holding it during centrifugation and preparation of autologous PRP / Fluid-PRF (intended purpose stated by the manufacturer).
  • PRP / Fluid-PRF is administered according to the treatment indicated by the physician.

Key features

Closed system

Limits exposure to external contaminants.

Anticoagulant-free

No anticoagulant and no separation gel; purely physical separation.

Single spin

5 minutes at 1,500 rpm / 420 × g, in a swing-out rotor centrifuge.

18 mL syringe

18 mL of whole blood yield about 8.5 mL of PRP / Fluid-PRF.

Luer-Lock compatible

Flexible system integration and secure fluid transfer.

Made in Austria

EN ISO 13485 quality system; MDR-certified device.

Product gallery
Exprecell™ Single Syringe System — packaging and device (Croma material)
Exprecell™ Single Syringe System — packaging and device (Croma material)
Exprecell™ — the single syringe for blood draw, centrifugation and extraction (Croma material)
Exprecell™ — the single syringe for blood draw, centrifugation and extraction (Croma material)
Exprecell™ — blood layers separated after centrifugation (Croma material)
Exprecell™ — blood layers separated after centrifugation (Croma material)
Exprecell™ — handling the device (Croma material)
Exprecell™ — handling the device (Croma material)
Exprecell™ — drawing PRP / Fluid-PRF through the central channel (Croma material)
Exprecell™ — drawing PRP / Fluid-PRF through the central channel (Croma material)
Technical specifications
Intended purpose
Aspiration of venous blood, holding it during centrifugation and preparation of autologous PRP / Fluid-PRF
Capacity
18 mL of whole blood
PRP / Fluid-PRF yield
8.45 ± 1.3 mL (mean)
Platelet concentration factor
2.3 ± 0.3 over baseline
Platelet recovery
67.2% ± 16.0% (mean)
Leukocyte / erythrocyte reduction
> 95% / > 99%
Extracellular vesicles
7,450,238 ± 1,563,853 /mL (mean); 80% platelet-derived
Centrifugation
5 minutes, at most 1,500 rpm (420 × g), swing-out rotor centrifuge (for example Hettich Rotofix 32-A, Drucker Horizon 24-AH)
Components
18 mL syringe barrel; Luer stopper (male Luer-Lock); plunger stopper/sealing with central aperture; plunger rod with central channel; thumb press with female Luer stopper
Blood draw
Luer-Lock needle, for example a 21 G butterfly needle
Manufacturer
CROMA-PHARMA GmbH, Leobendorf, Austria

Clinical evidence

A selection of publications and studies that mention use of the system. Summaries are indicative; for details, consult the original source.

Anticoagulant-free preparation of autologous PRP / f-PRF: a pre-clinical comparative performance study

Assinger A., Pirabe A., Santol J., Muhammad A., Kuroki-Hasenöhrl D. · Frontiers in Pharmacology, 2026

Pre-clinical study on blood from 16 healthy volunteers, comparing Exprecell™ with the Arthrex ACP® Double-Syringe system at the same centrifugation (420 × g, 5 minutes). Exprecell™ yielded 20% more f-PRF volume, while platelet count and function, detectable growth factors and extracellular vesicle profiles were comparable between systems. The authors note that the clinical benefit must be shown in future studies; two of the authors are Croma employees.

Mean f-PRF yield: 8.45 ± 1.3 mL vs 6.95 ± 1.0 mL; platelet concentration factor: 2.3 ± 0.3 vs 2.1 ± 0.6; leukocyte reduction: > 95% vs > 97%; erythrocyte reduction: > 99% in both.
View source
Certifications & compliance
CE 2797 marking MDR EN ISO 13485 (manufacturer quality system)

Would you like information about Exprecell™ — Single syringe system for autologous PRP / Fluid-PRF?

The Ronda Medical team provides details about availability, configurations, and technical support.

Contact the team