SYM Medical

Cerebral Corridor Creator (CCC) — Balloon-assisted brain retractor

A balloon-assisted brain retractor with a transparent tube that opens a surgical corridor to deep intracranial lesions by radial dilation of the brain tissue.

The CCC set: balloon catheter, two transparent tubular retractors, inner stylet and syringe
Upcoming event · 17 November 2026

SYM Medical webinar: clinical experience with the Cerebral Corridor Creator

Details and registration
Clinical description

The Cerebral Corridor Creator (CCC) is a brain tissue retractor and holder that creates the access pathway for neurosurgical procedures on deep lesions. The set contains a balloon catheter and a transparent tubular retractor; depending on the configuration, it includes one or two retractors of different sizes and an adaptor.

The balloon is advanced along the planned trajectory and repeatedly inflated and deflated. The 360° dilation applies pressure evenly and radially to the brain tissue, which, according to the manufacturer, limits damage to the surrounding cortex and white matter. Successive inflations form a pre-channel and also allow intracranial pressure to be released at the right moment.

The balloon catheter is hollow. With a syringe connected to the catheter, part of the fluid can be withdrawn to confirm the lesion position and reduce intracranial pressure. The tubular retractor is then introduced over the inflated balloon: together they form a bullet-shaped tip that makes placement easier. Once the corridor is formed, the catheter is withdrawn and the retractor stays in place until the end of the procedure.

The transparent retractor gives a direct view of the lesion and surrounding tissue, maintains the corridor and protects the brain tissue from accidental injury and collapse. The wall carries a dual depth scale, the handle has a built-in irrigation line, and the stepped handle fits common fixation devices. The system is compatible with neuronavigation and can be used in endoscopic or microsurgical keyhole surgery.

Indications
  • Hypertensive intracerebral haemorrhage: basal ganglia, lobes, thalamus, ventricles.
  • Access to deep intracranial lesions in minimally invasive surgery.
  • Retractor for endoscopic or microsurgical keyhole surgery.

Key features

360° balloon dilation

Even radial pressure; repeated inflation and deflation for gradual corridor formation.

Hollow catheter

For fluid aspiration and intracranial decompression.

Bullet-shaped tip

Formed by the balloon and retractor together, which makes placement easier.

Transparent retractor

A tube with a dual depth scale and an irrigation line built into the handle.

Stepped handle

Compatible with common fixation devices.

Neuronavigation compatible

Including the Brainlab and Medtronic workflows shown in the manufacturer videos.

Videos

For healthcare professionals. Some of the videos contain intraoperative footage.

CCC: key steps0:56
CCC: instructions for use6:46
CCC with Brainlab navigation2:57
CCC with Medtronic navigation3:33
CCC: haematoma evacuation1:35
CCC: intracranial surgical access1:02
Product gallery
The CCC set: balloon catheter, two transparent tubular retractors, inner stylet and syringe
The CCC set: balloon catheter, two transparent tubular retractors, inner stylet and syringe
The inflated CCC balloon, showing the direction of 360° radial pressure
The inflated CCC balloon, showing the direction of 360° radial pressure
The transparent CCC tubular retractor with its dual depth scale
The transparent CCC tubular retractor with its dual depth scale
The steps of using the CCC, from balloon placement to retractor removal
The steps of using the CCC, from balloon placement to retractor removal
Technical specifications
Components
Balloon catheter, tubular retractor, inner stylet; adaptor depending on configuration
Tubular retractor DG-5015B
Inner diameter 15 mm, length 50 mm
Tubular retractor DG-7013B
Inner diameter 13 mm, length 70 mm
Balloon catheter (flexible retractor)
8F; balloon of 6, 8, 10, 12, 13, 14, 15, 16, 17 or 18 mm (±2 mm); length 50 ± 5 mm
Balloon catheter codes
QK-06L24, QK-08L24, QK-10L24, QK-12L22 to QK-18L22
Manufacturer
Shenzhen Shineyard Medical Device Co., Ltd., Shenzhen, China

Clinical evidence

A selection of publications and studies that mention use of the system. Summaries are indicative; for details, consult the original source.

Application of microballoon-assisted cerebral corridor creator in neuroendoscopic surgery for basal ganglia hemorrhage

Hu Y.Z., Wen S.H., Zhang L.Y., Long Q.S., Tan Y.J., Wen Y.Q., Wei X.B., Yu Y.Q., Li X.S. · The Third People's Hospital of Huizhou, China (PDF)

97 patients with spontaneous basal ganglia haemorrhage were randomised: 46 had neuroendoscopic surgery with the CCC and 51 had a craniotomy. The CCC group had shorter operating time and less blood loss.

Haematoma evacuation rate: 90.5% versus 78.7%; good outcomes at 6 months: 72% versus 51%.
View source

Cerebral corridor creator for resection of trigone ventricular tumors: Two case reports

Liu X.W., Lu W.R., Zhang T.Y., Hou X.S., Fa Z.Q., Zhang S.Z. · World Journal of Clinical Cases, 2022

Two cases of trigone ventricular tumours with total removal using the CCC and no additional neurological deficit. Optic radiation fibres were preserved on DTI. The authors consider the CCC a promising alternative, based on two cases.

View source

Would you like information about Cerebral Corridor Creator (CCC) — Balloon-assisted brain retractor?

The Ronda Medical team provides details about availability, configurations, and technical support.

Contact the team